3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump

Product Details
Customization: Available
Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Single & Three Phase
Still deciding? Get samples of US$ 101/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO9001:2015
Terms of Payment
LC, T/T, D/P, PayPal, Western Union, Small-amount payment
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
  • 3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Model Selection
  • Janson Controls
Overview

Basic Info.

Model NO.
FC610
Switch Mode
PWM Control
Main Circuit Type
Voltage
Voltage of Power Supply
Low Voltage Variable-Frequency Drive
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Constant Torque Universal Type
Brand
Janson Controls
Certificate
ISO9001, CE
Control Mode
V/F
Input Voltage
220V/380V
Output Power
0.4~7.5kw
Output Frequency
0~600Hz
Used for
Water Pump
Transport Package
Cartons/ Piece
Specification
Input Voltage Range -15%~+20%
Trademark
FC
Origin
China
HS Code
8504409999
Production Capacity
10000PCS/ Month

Product Description

Product Description

3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump
 

Product Parameters

Electrical Specification
Input Voltage Single Phase/Three Phase 200~240V,  Three Phase 380~440V
Fluctuate no more than±10%
,Imbalance Rate <3%
Input Frequency 50/60Hz ± 5%
Output Voltage 0V~Input Voltage
10~60Hz
Performance
Overload Capacity 110% rated output current for 1 minute
Control Method V/F Control
Run Command Setting Method Operation panel setting, analog setting, communication setting
Speed Setting Method Digital setting, analog setting/pulse setting, communication setting
Protective function
Overvoltage Stall Bus voltage automatic control to prevent overvoltage fault
Automatic Current Limiting Protection Output current is automatically limited to prevent over-current faults
Overload Pre-Alarm & Alarm Overload Pre-warning and protection
Output Phase Loss Protection Output phase loss automatic detection and alarm function
Overvoltage & Overflow Stall Control Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping
Output Short-to-Ground Protection Effective protection function for output short circuit to ground
Output Phase-to-Phase Short Circuit Protection Output interphase short circuit effective protection function
Input & Output
External analog power supply +24V,load capacity 100mA
Analog Input AI1:Voltage 0~10V/0-20mA
AI2
:Voltage 0~10V/0-20mA
Digital Input DI1,DI2
Digital Output DO1
Relay output TA/TB/TC:Contact rating 250VAC/3A Or 30VDC/1A
MUDBUS Communication A+,B-
Operation Display
LED Display 4 digit LED digital tube
Output frequency, output current, current pressure, set pressure and fault code etc.
Indicator Light 4 status lights
Environmental characteristics
Working Temperature -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC
Storage Environment Temperature -40~+70ºC
Altitude Less than 1000 meters, derating is required for more than 1000 meters
Humidity Less than 95%RH, no condensation
Vibration resistance 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3)
Protection Degree IP54
Pollution Level Class 2 (dry, non-conductive dust pollution)
 

Model Selection

Item No. Adaptable Motor (kW) Input Current (A) Output Current (A) Rate Capacity (kVA) W
(mm)
H
(mm)
D
(mm)
W1
(mm)
H1
(mm)
Diameter
(mm)
GW
(kg)
3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC610-4T-2.2P 2.20 5.80 5.10 4.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-4T-4.0P 4.00 10.00 8.60 5.90 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-4T-5.5P 5.50 14.60 12.50 8.60 200.00 235.00 146.00 129.00 225.00 Ø4 3.85
FC610-4T-7.5P 7.50 20.50 17.50 12.00 200.00 235.00 146.00 129.00 225.00 Ø4 3.85
FC610-4T-11P 11.00 28.00 25.00 16.00 200.00 235.00 146.00 129.00 225.00 Ø4 4.00
1 Phase Input and 3 Phase Output  220V (-15%~+15% Tolerance)
FC610-2S-0.75P 0.75 8.20 4.00 1.50 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-2S-1.5P 1.50 14.00 7.00 3.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
FC610-2S-2.2P 2.20 23.00 9.60 4.00 126.00 173.00 136.00 101.00 158.00 Ø3.5 2.48
 

Janson Controls

3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump3 Phase 380V 7.5kw Variable Frequency Inverter VFD Special for Water Pump