Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single & Three Phase |
Still deciding? Get samples of US$ 101/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V, Three Phase 380~440V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage 10~60Hz |
Performance | |
Overload Capacity | 110% rated output current for 1 minute |
Control Method | V/F Control |
Run Command Setting Method | Operation panel setting, analog setting, communication setting |
Speed Setting Method | Digital setting, analog setting/pulse setting, communication setting |
Protective function | |
Overvoltage Stall | Bus voltage automatic control to prevent overvoltage fault |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Overvoltage & Overflow Stall Control | Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping |
Output Short-to-Ground Protection | Effective protection function for output short circuit to ground |
Output Phase-to-Phase Short Circuit Protection | Output interphase short circuit effective protection function |
Input & Output | |
External analog power supply | +24V,load capacity 100mA |
Analog Input | AI1:Voltage 0~10V/0-20mA AI2:Voltage 0~10V/0-20mA |
Digital Input | DI1,DI2 |
Digital Output | DO1 |
Relay output | TA/TB/TC:Contact rating 250VAC/3A Or 30VDC/1A |
MUDBUS Communication | A+,B- |
Operation Display | |
LED Display | 4 digit LED digital tube Output frequency, output current, current pressure, set pressure and fault code etc. |
Indicator Light | 4 status lights |
Environmental characteristics | |
Working Temperature | -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC |
Storage Environment Temperature | -40~+70ºC |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
Protection Degree | IP54 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) |
H (mm) |
D (mm) |
W1 (mm) |
H1 (mm) |
Diameter (mm) |
GW (kg) |
3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||||
FC610-4T-2.2P | 2.20 | 5.80 | 5.10 | 4.00 | 126.00 | 173.00 | 136.00 | 101.00 | 158.00 | Ø3.5 | 2.48 |
FC610-4T-4.0P | 4.00 | 10.00 | 8.60 | 5.90 | 126.00 | 173.00 | 136.00 | 101.00 | 158.00 | Ø3.5 | 2.48 |
FC610-4T-5.5P | 5.50 | 14.60 | 12.50 | 8.60 | 200.00 | 235.00 | 146.00 | 129.00 | 225.00 | Ø4 | 3.85 |
FC610-4T-7.5P | 7.50 | 20.50 | 17.50 | 12.00 | 200.00 | 235.00 | 146.00 | 129.00 | 225.00 | Ø4 | 3.85 |
FC610-4T-11P | 11.00 | 28.00 | 25.00 | 16.00 | 200.00 | 235.00 | 146.00 | 129.00 | 225.00 | Ø4 | 4.00 |
1 Phase Input and 3 Phase Output 220V (-15%~+15% Tolerance) | |||||||||||
FC610-2S-0.75P | 0.75 | 8.20 | 4.00 | 1.50 | 126.00 | 173.00 | 136.00 | 101.00 | 158.00 | Ø3.5 | 2.48 |
FC610-2S-1.5P | 1.50 | 14.00 | 7.00 | 3.00 | 126.00 | 173.00 | 136.00 | 101.00 | 158.00 | Ø3.5 | 2.48 |
FC610-2S-2.2P | 2.20 | 23.00 | 9.60 | 4.00 | 126.00 | 173.00 | 136.00 | 101.00 | 158.00 | Ø3.5 | 2.48 |