• Welcome to Consult Economical Water Pump AC Drive Form Janson Controls
  • Welcome to Consult Economical Water Pump AC Drive Form Janson Controls
  • Welcome to Consult Economical Water Pump AC Drive Form Janson Controls
  • Welcome to Consult Economical Water Pump AC Drive Form Janson Controls
  • Welcome to Consult Economical Water Pump AC Drive Form Janson Controls
  • Welcome to Consult Economical Water Pump AC Drive Form Janson Controls

Welcome to Consult Economical Water Pump AC Drive Form Janson Controls

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Single & Three Phase
Principle of Work: V/F Control Transducer
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 90/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product selection table
  • Product parameter list
  • Detailed introduction
  • FAQ
Overview

Basic Info.

Model NO.
FC610
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Simple Type, Water Pump Type
Brand
Janson Controls
Certificate
ISO9001,CE
Control Mode
V/F Control
Input Voltage
1/3 Phase 220V~240V, 3 Phase 380V
Qutput Voltage
50/60Hz
Qutput Power
0.75~11kw
Qutput Frequency
0~600Hz
Protection Degree
IP54
Transport Package
Cartons/ Piece
Specification
Input Voltage Range -15%~+20%
Trademark
FC
Origin
China
HS Code
8504409999
Production Capacity
10000PCS/ Month

Product Description


 

Product selection table
  
Item No. Adaptable Motor (kW) Input Current (A) Output Current (A) Rate Capacity (kVA) W
(mm)
H
(mm)
D
(mm)
W1
(mm)
H1
(mm)
Diameter
(mm)
GW
(kg)
3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC610-4T-2.2P 2.20  5.80  5.10  4.00  126.00  173.00  136.00  101.00  158.00  Ø3.5 2.48 
FC610-4T-4.0P 4.00  10.00  8.60  5.90  126.00  173.00  136.00  101.00  158.00  Ø3.5 2.48 
FC610-4T-5.5P 5.50  14.60  12.50  8.60  200.00  235.00  146.00  129.00  225.00  Ø4 3.85 
FC610-4T-7.5P 7.50  20.50  17.50  12.00  200.00  235.00  146.00  129.00  225.00  Ø4 3.85 
FC610-4T-11P 11.00  28.00  25.00  16.00  200.00  235.00  146.00  129.00  225.00  Ø4 4.00 
1 Phase Input and 3 Phase Output  220V (-15%~+15% Tolerance)
FC610-2S-0.75P 0.75  8.20  4.00  1.50  126.00  173.00  136.00  101.00  158.00  Ø3.5 2.48 
FC610-2S-1.5P 1.50  14.00  7.00  3.00  126.00  173.00  136.00  101.00  158.00  Ø3.5 2.48 
FC610-2S-2.2P 2.20  23.00  9.60  4.00  126.00  173.00  136.00  101.00  158.00  Ø3.5 2.48 

Product parameter list
Electrical Specification
Input Voltage Single Phase/Three Phase 200~240V,  Three Phase 380~440V
Fluctuate no more than±10%,Imbalance Rate <3%
Input Frequency 50/60Hz ± 5%
Output Voltage 0V~Input Voltage
10~60Hz
Performance
Overload Capacity 110% rated output current for 1 minute
Control Method V/F Control
Run Command Setting Method Operation panel setting, analog setting, communication setting
Speed Setting Method Digital setting, analog setting/pulse setting, communication setting
Protective function
Overvoltage Stall Bus voltage automatic control to prevent overvoltage fault
Automatic Current Limiting Protection Output current is automatically limited to prevent over-current faults
Overload Pre-Alarm & Alarm Overload Pre-warning and protection
Output Phase Loss Protection Output phase loss automatic detection and alarm function
Overvoltage & Overflow Stall Control Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping
Output Short-to-Ground Protection Effective protection function for output short circuit to ground
Output Phase-to-Phase Short Circuit Protection Output interphase short circuit effective protection function
Input & Output
External analog power supply +24V,load capacity 100mA
Analog Input AI1:Voltage 0~10V/0-20mA
AI2
:Voltage 0~10V/0-20mA
Digital Input DI1,DI2
Digital Output DO1
Relay output TA/TB/TC:Contact rating 250VAC/3A Or 30VDC/1A
MUDBUS Communication A+,B-
Operation Display
LED Display 4 digit LED digital tube
Output frequency, output current, current pressure, set pressure and fault code etc.
Indicator Light 4 status lights
Environmental characteristics
Working Temperature -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC
Storage Environment Temperature -40~+70ºC
Altitude Less than 1000 meters, derating is required for more than 1000 meters
Humidity Less than 95%RH, no condensation
Vibration resistance 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3)
Protection Degree IP54
Pollution Level Class 2 (dry, non-conductive dust pollution)

 
Detailed introduction


Welcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson ControlsWelcome to Consult Economical Water Pump AC Drive Form Janson Controls