Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Single Phase & Three Phase
Principle of Work: Vector Control & V/F Control
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 15/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product parameter list
  • Product selection table
  • Detailed introduction
Overview

Basic Info.

Model NO.
FC110C
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Elevator Special, Textile Special, Constant Torque Universal Type
Brand
Janson Controls
Certificate
ISO9001,CE
Control Mode
W/F, SVC, Fvc
Input Voltage
220V/380V/440V/480V
Qutput Power
0.4~400kw
Qutput Frequency
0~500Hz
Software Feature
European Fire Mode
Used for
Most Industrial Motor Drive
Transport Package
Cartons/ Piece
Specification
Input Voltage Range -15%~+20%
Trademark
FC
Origin
China
HS Code
8504409999
Production Capacity
10000PCS/ Month

Product Description

Product parameter list
Item No. Adaptable Motor (kW) Input Current (A) Output Current (A) Rate Capacity (kVA) W
(mm)
H
(mm)
D
(mm)
W1
(mm)
H1
(mm)
Diameter
(mm)
GW
(kg)
3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC110C-4T-0.75GB/1.5PB 0.75/1.5 3.4/5.0 2.1/3.8 1.5/3.0 92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-4T-1.5GB/2.2PB 1.5/2.2 5.0/5.8 3.8/5.1 3.0/4.0 92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-4T-2.2GB/3.0PB 2.2/3.0 5.8/8.0 5.1/6.8 4.0/4.9 92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-4T-3.0GB/4.0PB 3.0/4.0 8.0/10.5 6.8/9.0 4.9/5.9 92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-4T-4.0GB/5.5PB 4.0/5.5 10.5/14.6 9.0/13.0 5.9/8.9 92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-4T-5.5GB/7.5PB 5.5/7.5 14.6/20.5 13.0/17.0 8.9/11.0 109.00  219.00  173.00  98.00  208.00  Ø5.5 2.40 
FC110C-4T-7.5GB/11PB 7.5/11 20.5/26.0 17.0/25.0 11.0/17.0 109.00  219.00  173.00  98.00  208.00  Ø5.5 2.40 
FC110C-4T-11GB/15PB 11/15 26.0/35.0 25.0/32.0 17.0/21.0 130.00  261.00  182.00  119.00  250.00  Ø5.5 3.80 
FC110C-4T15GB/18.5PB 15/18.5 35.0/38.5 32.0/37.0 21.0/24.0 130.00  261.00  182.00  119.00  250.00  Ø5.5 3.80 
FC110C-4T18.5GB/22PB 18.5/22 38.5/46.5 37.0/45.0 24.0/30.0 190.00  293.00  199.00  167.00  282.00  Ø5.5 6.50 
FC110C-4T-22GB/30PB 22/30 46.5/62.0 45.0/60.0 30.0/40.0 190.00  293.00  199.00  167.00  282.00  Ø5.5 6.60 
FC110C-4T-30G/37P 30/37 62.0/76.0 60.0/75.0 40.0/57.0 250.00  426.00  210.00  210.00  410.00  Ø9 14.60 
FC110C-4T-37G/45P 37/45 76.0/92.0 75.0/91.0 57.0/69.0 250.00  426.00  210.00  210.00  410.00  Ø9 14.60 
FC110C-4T-45G/55P 45/55 92.0/113.0 91.0/112.0 69.0/85.0 300.00  492.00  236.00  266.00  473.00  Ø9 19.50 
FC110C-4T-55G/75P 55/75 113.0/157.0 112.0/150.0 85.0/114.0 300.00  492.00  236.00  266.00  473.00  Ø9 19.80 
FC110C-4T-75G/90P 75/90 157.0/180.0 150.0/176.0 114.0/134.0 320.00  555.00  230.00  230.00  536.00  Ø12 26.50 
FC110C-4T-90G/110P 90/110 180.0/214.0 176.0/210.0 134.0/160.0 410.00  634.00  240.00  320.00  611.00  Ø12 48.30 
FC110C-4T-110G/132P 110/132 214.0/256.0 210.0/253.0 160.0/192.0 410.00  634.00  240.00  320.00  611.00  Ø12 49.00 
FC110C-4T-132G/160P 132/160 256.0/307.0 253.0/304.0 192.0/231.0 475.00  692.00  347.00  320.00  669.00  Ø12 72.40 
FC110C-4T-160G/185P 160/185 307.0/340.0 304.0/330.0 231.0/236.0 475.00  692.00  347.00  320.00  669.00  Ø12 73.50 
FC110C-4T-185G/200P 185/200 340.0/385.0 330.0/377.0 236.0/250.0 420.00  790.00  366.00  310.00  764.00  Ø12 80.00 
FC110C-4T-200G/220P 200/220 385.0/430.0 377.0/426.0 250.0/280.0 420.00  790.00  366.00  310.00  764.00  Ø12 80.00 
FC110C-4T-220G/250P 220/250 430.0/468.0 426.0/465.0 280.0/355.0 490.00  810.00  370.00  360.00  785.00  Ø12 93.50 
FC110C-4T-250G/280P 250/280 468.0/525.0 465.0/520.0 355.0/396.0 490.00  1110.00  370.00  360.00  1085.00  Ø12 126.00 
FC110C-4T-280G/315P 280/315 525.0/590.0 520.0/585.0 396.0/445.0 650.00  1190.00  370.00  520.00  1159.00  Ø14 164.00 
FC110C-4T-315G/355P 315/355 590.0/665.0 585.0/650.0 445.0/500.0 650.00  1190.00  370.00  520.00  1159.00  Ø14 165.00 
FC110C-4T-355G/400P 355/400 665.0/785.0 650.0/725.0 500.0/565.0 650.00  1190.00  370.00  520.00  1159.00  Ø14 166.00 
FC110C-4T-400G/450P 400/450 785.0/883.0 725.0/820.0 565.0/630.0 650.00  1190.00  370.00  520.00  1159.00  Ø14 167.00 
1/3 Phase Input and 3 Phase Output  220V (-15%~+15% Tolerance)
FC110C-2S/T-0.75G 0.75  8.20  4.00  1.50  92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-2S/T-1.5G 1.50  14.00  7.00  3.00  92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
FC110C-2S/T-2.2G 2.20  23.00  10.00  4.00  92.00  172.00  152.00  81.00  162.00  Ø4.5 1.70 
 
Product selection table
 
Item Specifications
Basic functions Maximum frequency Vector control: 300.00Hz
V/F control: 3200Hz
Carrier frequency 0.5kHz-16kHz, The carrier frequency can be adjusted automatically based on the load features.
Input frequency resolution Digital setting: 0.01Hz
Analog setting: maximum frequency × 0.025%
Control mode Open-loop vector control (SVC)
Closed-loop vector control(FVC)
V/F Control
Start-up torque G type: 0.5Hz/150% (SVC), 0Hz/180% (FVC)
P type: 0.5Hz/100%.
Speed range 1:100 (SVC) 1:1000(FVC)
Steady speed accuracy ±0.5%(SVC) ±0.02%(FVC)
Torque control accuracy ±5%(FVC)
Overload capacity G type: 150% rated current 60s; 180% rated current 3S
 P type: 120% rated current 60s; 150% rated current 3S
Automatic torque lifting Manual torque lifting 0.1%-30.0%.
Three ways of V/F curve Straight-line type;
Multi-point type;
N-power V/F curve (1.2 power, 1.4 power, 1.6power, 1.8power, 2power ,square)
Two ways of V/F separation Two types: complete separation and half separation
Ramp mode Straight-line ramp or S-curve ramp, Four groups of acceleration /deceleration time with the range of 0.0s-6500.0s
DC braking 0.00Hz - maximum output frequency,
Braking time: 0.0s - 36.0s
Braking action current value: 0.0% - 100.0%.
JOG control JOG frequency range: 0.00Hz-50.00Hz,
JOG acceleration / deceleration time: 0.0s-6500.0s
On board multiple preset speeds It implements up to 16 speeds via the simple PLC function or combination of DI terminal states.
Built-in PID It realizes process-controlled closed-loop control system easily.
Automatic voltage adjustment (AVR) It can keep constant output voltage automatically when the main voltage changes.
Torque limitation and control It cam limit the torque automatically and prevent frequent over current tripping during the running process.
Individualized functions Safety self-inspection of power-on peripheral equipment It can realize the safety detection of peripheral equipment such as grounding, short circuit and so on.
Over-voltage and over-loss speed control Automatic limit of current and voltage during operation to prevent frequent over-current and over-voltage tripping
Fast current Limit Minimizing overcurrent fault and protecting frequency converter in normal operation
Common DC bus function It can realize common DC bus functions of multiple frequency converters.
QUICK key User-defined shortcut menu
MF.K key Programmable key: command channel switching/forward and reverse running/JOG running function selection
Textile swing frequency control Given length control function
Timing control Timing control function: setting time range 0h-65535h
Running channel Running command source Three channels: operation panel, control terminal and serial communication port .They can be switched over between these sources in various ways.
Frequency sources There are total 10 of frequency sources, such as digital setting, analog voltage setting, analog current setting,pulse setting and serial communication port setting. They can be switched over these sources in various ways.
Auxiliary frequency command 10 kinds of auxiliary frequency instructions. It can realize auxiliary frequency fine adjustment and frequency synthesis flexibly.
Input terminal Seven digital Input terminals, of which X5 can be used as high-speed pulse input. Compatible with active PNP
Or NPN input mode, two analog input terminals, can be used as voltage or current input.
Output terminal A high-speed pulse output terminal DO (optional open collector type), 0 kHz-100 kHz square wave signal output,
It can realize the output of set frequency, output frequency and other physical quantities.
Three digital output terminals and two relay output terminals
Two analog output terminals, 0/4mA-20mA or 0V-10V, can realize setting frequency and transmission.
Output frequency and other physical quantities
Display and keyboard LED display Display monitoring parameters, output frequency, set frequency, bus voltage, etc.
Keyboard lock and function selection To realize partial or total lock of keys, define the scope of action of some keys, in order to prevent misoperation.
Protection Function Short circuit detection , input and output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection , overheat protection and overload protection
Optional parts Brake assembly
Ambient Installation location Indoor ,free from direct sunlight, dust-free, corrosive gases, combustible gases, oil smoke, vapour, drip or salt, etc.
Altitude <1000m
Ambient temperature -10°C~+40°C (ambient temperature is 40°C~50°C , please derate to use)
Humidity Less than 95 k% RH, no water droplet condensation
Vibration less than 5.9m/s² (0.6g)
Storage temperature -20ºC~+60ºC
IP level IP20
Pollution grade PD2
Power distribution system TN,TT

Detailed introduction

Robotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous MotorRobotsy Warranty Time 36 Months 0.4kw 220/380VAC VSD VFD for Three-Phase Asynchronous Motor