Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V, Three Phase 380~440V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage |
Output Frequency | Vector Control:0~300Hz V/F Control:0~3200Hz |
Performance | |
Overload Capacity | 150% rated output current for 1 minute, 180% rated output current for 2 seconds |
Control Method | Open-loop vector control (SVC), V/F control |
Run Command Setting Method | Operation Panel Setting, External Terminal Setting,Communication Setting |
Speed Setting Method | Digital setting, analog setting/pulse setting, communication setting |
Speed Setting Resolution | Digital setting: 0.01Hz, Analog setting: 1% X maximum frequency |
Speed Control Accuracy | SVC:±0.5% |
Speed Control Range | SVC:1:100 |
Torque Control Response | SVC:<200ms |
Starting Torque | SVC:150% rated torque/0.5Hz |
Special Feature | |
Programmable Input & Output Terminals | Input& Output terminal function can be edited |
Process PID Adjustment Function | Built-in process PID module |
Simple PLC Function | Built-in simple PLC module, which can realize timing and multi-segment frequency output |
Textile Wobble Function | Built-in textile swing frequency function module |
Protective function | |
Overvoltage Stall | Bus voltage automatic control to prevent overvoltage fault |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Overvoltage & Overflow Stall Control | Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping |
Output Short-to-Ground Protection | Effective protection function for output short circuit to ground |
Output Phase-to-Phase Short Circuit Protection | Output interphase short circuit effective protection function |
Input & Output | |
External analog power supply | +10V,load capacity 100mA |
External digital power supply | +24V,load capacity 200mA |
Analog Input | AI1:Voltage 0~10V/0-20mA |
Analog Voltage Output | AOV:0~10V |
Analog Current Output | AOI:0~20mA |
Digital Input | DI1~DI5(DI5 can be selected as a high-speed pulse signal) |
Digital Output | FM:FM can be selected as high-frequency pulse signal output |
Relay output | TA/TB/TC:Contact rating 250VAC/3A or 30VDC/1A |
MODBUS Communication | A+,B- |
Operation Display | |
LED Display | Set frequency, output frequency, output voltage, output current, motor speed, output torque, digital terminals, status parameters, programming menu parameters and fault codes etc. |
Indicator Light | 3 units indicators, 3 status indicators |
Environmental characteristics | |
Working Temperature | -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC |
Storage Environment Temperature | -40~+70ºC |
Application | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2~9Hz, 10m/s² at 9~200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |
Certification | |
CE | The whole series has passed CE certification |
Optional accessories | |
Keypad | The whole series supports external keyboard through standard network cable |
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) |
H (mm) |
D (mm) |
W1 (mm) |
H1 (mm) |
Diameter (mm) |
GW (kg) |
1 Phase Input and 3 Phase Output 220V (-15%~+15% Tolerance) | |||||||||||
FC100E-2S-0.4G | 0.40 | 6.50 | 2.10 | 0.70 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.30 |
FC100E-2S-0.75G | 0.75 | 8.20 | 4.00 | 1.50 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.30 |
FC100E-2S-1.5G | 1.50 | 14.00 | 7.00 | 3.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.30 |
FC100E-2S-2.2G | 2.20 | 23.00 | 9.60 | 4.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.30 |
FC100E-2S-4.0G | 4.00 | 39.00 | 16.50 | 5.90 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 3.50 |
FC100E-2S-5.5G | 5.50 | 60.00 | 25.00 | 8.50 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.00 |
3 Phase Input and 3 Phase Output 220V (-15%~+15% Tolerance) | |||||||||||
FC100E-2T-4.0G | 4.00 | 19.00 | 16.50 | 5.90 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 4.00 |
FC100E-2T-5.5G | 5.50 | 28.00 | 25.00 | 8.50 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.00 |
FC100E-2T-7.5G | 7.50 | 35.00 | 30.00 | 11.00 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.20 |
FC100E-2T-11G | 11.00 | 47.00 | 45.00 | 16.00 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.60 |
3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||||
FC100E-4T-0.75G | 0.75 | 3.40 | 2.10 | 1.50 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-4T-1.5G | 1.50 | 5.00 | 3.80 | 3.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-4T-2.2G | 2.20 | 5.80 | 5.10 | 4.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-4T-4.0G | 4.00 | 10.50 | 9.00 | 5.90 | 95.00 | 180.00 | 120.00 | 83.00 | 168.00 | Ø5 | 1.50 |
FC100E-4T-5.5G | 5.50 | 14.60 | 13.00 | 8.90 | 95.00 | 180.00 | 120.00 | 83.00 | 168.00 | Ø5 | 3.50 |
FC100E-4T-7.5G | 7.50 | 19.00 | 17.00 | 11.00 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 4.00 |
FC100E-4T-11G | 11.00 | 28.00 | 25.00 | 16.00 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.00 |
FC100E-4T-15G | 15.00 | 35.00 | 32.00 | 21.00 | 106.50 | 240.50 | 148.00 | 96.00 | 230.00 | Ø5 | 5.20 |
1 Phase lnput 220V and 3 Phase Output 380V(-15%-+15% Tolerance) | |||||||||||
FC100E-2S4T-0.75G | 0.75 | 7.50 | 2.50 | 1.50 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-2S4T-1.5G | 1.50 | 11.00 | 3.70 | 3.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-2S4T-2.2G | 2.20 | 15.00 | 5.00 | 4.00 | 85.00 | 142.00 | 116.00 | 73.00 | 136.00 | Ø5 | 1.50 |
FC100E-2S4T-4.0G | 4.00 | 26.00 | 8.50 | 5.90 | 95.00 | 180.00 | 120.00 | 83.00 | 168.00 | Ø5 | 1.50 |
FC100E-2S4T-5.5G | 5.50 | 39.00 | 13.00 | 8.90 | 95.00 | 180.00 | 120.00 | 83.00 | 168.00 | Ø5 | 3.50 |
Something you will care:
1. Can I get some samples?
Yes, Sample order is available for quality check and market test .But you have to pay for it .
2. What's delivery time?
It usually takes about 3-5 working days for small order and 10-15 days for big order .
3. What's your payment terms?
We usually accept all kinds of payment terms .Such as T/T,L/C, Western Union.Cash.
4. What's your warranty terms?
We offer 24 months warranty time .
5. Do you have the products in stock?
Depends on your request ,We have standard models in stock. Some special products and big order will be newly produced according to your order .
6. Can I mix different power in one container .
Yes ,Different models can be mixed up in one container ,even one order .
7. How does your factory do the quality control?
Quality is priority ,we always attach the importance to quality control from the beginning to the end of the production .every product will be fully assembled and carefully tested before packing and shipping .
8. Can you sell spare parts ?
If you are using our products .we can sell spare parts to you . But we couldn't sell the half-finished products.
9.I would like to know if you have a partner for export?
Yes .We have the right to export and can sell electrical product all over the world..
10. Can you make the inverter and soft starter control boards (switchgear)?
Yes. We have a lot of experience to design frequency inverter and soft starter cabinet according to your request,and our factory can do soft starter by ourselves.
11.Can the inverter connect with computer?
Yes .All inverters have built-in RS485 port .and support Modbus communication protocol.
12.How can I trust you ?