• 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator
  • 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator
  • 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator
  • 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator
  • 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator
  • 15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator

15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator

Application: High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer
Output Type: Single & Three Phase
Principle of Work: Vector Control & V/F Control
Switch Mode: PWM Control
Main Circuit Type: Voltage
Voltage of Power Supply: Low Voltage Variable-Frequency Drive
Samples:
US$ 235/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Model Selection
  • Janson Controls
Overview

Basic Info.

Model NO.
FC320L
Link of Transformation
AC-DC-AC Variable-Frequency Drive
Nature of DC Power
Voltage Variable-Frequency Drive
Function
Elevator Special, Textile Special, Constant Torque Universal Type
Brand
Janson Controls
Certificate
ISO9001, CE
Control Mode
V/F, SVC, Fvc
Input Voltage
220V/380V/440V/480V
Output Power
0.4~400kw
Output Frequency
0~500Hz
Software Feature
European Fire Mode
Used for
Most Industrial Motor Drive
Transport Package
Cartons/ Piece
Specification
Input Voltage Range -15%~+20%
Trademark
FC
Origin
China
HS Code
8504409999
Production Capacity
10000PCS/ Month

Product Description

Product Description

FC320L Series

Product Description

FC320L is a special vector control inverter for elevators developed and manufactured by Janson Controls. It absorbs the technical advantages of benchmark products in this industry, and optimizes and upgrades the algorithms of motor vector control and smooth curve calculation calculation. This product is the most practical, professional and easy-to-use dedicated inverter in the elevator industry!
 

Product Parameters

Basic Specifications
carrier frequency 2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted
Input Frequency Resolution digital setting: 0.01Hz
Analog setting: maximum frequency × 0.1%
Output Frequency Accuracy Digital setting: maximum frequency × ±0.01%
Analog setting: maximum frequency × ±0.01%
Control Method Open-loop vector control (SVC)/closed-loop vector control (FVC)/VF control
Starting torque 0.5Hz/180%(SVC); 0Hz/200%(FVC)
Speed Range 1:100(SVC)/1:1000(FVC) /1:50 (V/F)
Steady Speed Accuracy ±0.5%(SVC)  ±0.05%(FVC)
Overload Capacity 150% rated current for 60 seconds; 180% rated current for 1 second.
Motor Tuning Tuning with load; Tuning without load
Acceleration and deceleration curve Linear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations
Maintenance Control Can be specified by any number of speeds
Multi-Speed Operation Realize up to 8-speed operation
Automatic Voltage Regulator(AVR) When the grid voltage changes, it can automatically keep the output voltage constant
Display and operation
LED Display Can display setting frequency, output frequency, output voltage, output current and other parameters
Parameter Copy Fast copying of parameters with LED operator panel
Protective function Power-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection  40 kinds of protection
Key lock and function selection Realize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse
Personalization
Power-on peripheral equipment safety self-test It can realize safety detection of peripheral equipment such as grounding, short circuit etc.
Power Failure Emergency Operation Simple and convenient implementation of emergency operation plan
Over-speed protection Built-in elevator overspeed protection function; multiple action options
Judge speed deviation Built-in speed deviation detection function; discover potential hidden dangers of elevators in time
Forced Shift Function It has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom
Direct Docking Function Combined with direct docking commands for crawl-free operation
Motor temperature detection Timely judge the motor temperature to eliminate potential safety hazards
Start Compensation Three starting torque compensation methods: analog, digital, no weighing
QUICK Button User-defined shortcut menu
Timing Control Convenient timing control function
Input and output characteristics
Run Command Channel Two channels: operation panel given, control terminal given
Frequency Source 4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference
Input Terminal 10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode
2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input
Output Terminal 3 digital output terminals
2 relay output terminals
1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency
Environmental characteristics
Working temperature -10~+40ºC, up to 50ºC, air temperature change is less than 0.5ºC/min
Storage Temperature -40~+70ºC
Application Occasion Indoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc.
Altitude Less than 1000 meters, derating is required for more than 1000 meters
Humidity Less than 95%RH, no condensation
Vibration Resistance 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3)
Protection Degree IP20
Pollution Level Class 2 (dry, non-conductive dust pollution)
 

Model Selection

Item No. Adaptable Motor (kW) Input Current (A) Output Current (A) Rate Capacity (kVA) W
(mm)
H
(mm)
D
(mm)
W1
(mm)
H1
(mm)
Diameter
(mm)
GW
(kg)
1/3 Phase Input and 3 Phase Output  380V (-15%~+15% Tolerance)
FC320L-4T-7.5GB 7.50 19.00 17.00 11.00 208.00 322.00 192.00 190.00 305.00 Ø6 6.50
FC320L-4T-11GB 11.00 28.00 25.00 16.00 208.00 322.00 192.00 190.00 305.00 Ø6 6.80
FC320L-4T-15GB 15.00 35.00 32.00 21.00 208.00 322.00 192.00 190.00 305.00 Ø6 7.30
                       
Item No. Remark
PG-A4 AB Incrementall Encoder
PG-C Sin/Cos Encoder
PG-C2
PG-C3
PG-B UVW Encoder
MD32PG5 Absolute Encoder Endat and SSI Connector
 

Janson Controls

15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator15kw 380V Triple 50Hz/60Hz Frequency Inverter Use for Elevator

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now