Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single & Three Phase |
Still deciding? Get samples of US$ 235/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
FC320L Series
Product Description
FC320L is a special vector control inverter for elevators developed and manufactured by Janson Controls. It absorbs the technical advantages of benchmark products in this industry, and optimizes and upgrades the algorithms of motor vector control and smooth curve calculation calculation. This product is the most practical, professional and easy-to-use dedicated inverter in the elevator industry!
Basic Specifications | |
carrier frequency | 2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted |
Input Frequency Resolution | digital setting: 0.01Hz Analog setting: maximum frequency × 0.1% |
Output Frequency Accuracy | Digital setting: maximum frequency × ±0.01% Analog setting: maximum frequency × ±0.01% |
Control Method | Open-loop vector control (SVC)/closed-loop vector control (FVC)/VF control |
Starting torque | 0.5Hz/180%(SVC); 0Hz/200%(FVC) |
Speed Range | 1:100(SVC)/1:1000(FVC) /1:50 (V/F) |
Steady Speed Accuracy | ±0.5%(SVC) ±0.05%(FVC) |
Overload Capacity | 150% rated current for 60 seconds; 180% rated current for 1 second. |
Motor Tuning | Tuning with load; Tuning without load |
Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations |
Maintenance Control | Can be specified by any number of speeds |
Multi-Speed Operation | Realize up to 8-speed operation |
Automatic Voltage Regulator(AVR) | When the grid voltage changes, it can automatically keep the output voltage constant |
Display and operation | |
LED Display | Can display setting frequency, output frequency, output voltage, output current and other parameters |
Parameter Copy | Fast copying of parameters with LED operator panel |
Protective function | Power-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection 40 kinds of protection |
Key lock and function selection | Realize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse |
Personalization | |
Power-on peripheral equipment safety self-test | It can realize safety detection of peripheral equipment such as grounding, short circuit etc. |
Power Failure Emergency Operation | Simple and convenient implementation of emergency operation plan |
Over-speed protection | Built-in elevator overspeed protection function; multiple action options |
Judge speed deviation | Built-in speed deviation detection function; discover potential hidden dangers of elevators in time |
Forced Shift Function | It has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom |
Direct Docking Function | Combined with direct docking commands for crawl-free operation |
Motor temperature detection | Timely judge the motor temperature to eliminate potential safety hazards |
Start Compensation | Three starting torque compensation methods: analog, digital, no weighing |
QUICK Button | User-defined shortcut menu |
Timing Control | Convenient timing control function |
Input and output characteristics | |
Run Command Channel | Two channels: operation panel given, control terminal given |
Frequency Source | 4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference |
Input Terminal | 10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode 2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input |
Output Terminal | 3 digital output terminals 2 relay output terminals 1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency |
Environmental characteristics | |
Working temperature | -10~+40ºC, up to 50ºC, air temperature change is less than 0.5ºC/min |
Storage Temperature | -40~+70ºC |
Application Occasion | Indoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration Resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) |
H (mm) |
D (mm) |
W1 (mm) |
H1 (mm) |
Diameter (mm) |
GW (kg) |
1/3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||||||
FC320L-4T-7.5GB | 7.50 | 19.00 | 17.00 | 11.00 | 208.00 | 322.00 | 192.00 | 190.00 | 305.00 | Ø6 | 6.50 |
FC320L-4T-11GB | 11.00 | 28.00 | 25.00 | 16.00 | 208.00 | 322.00 | 192.00 | 190.00 | 305.00 | Ø6 | 6.80 |
FC320L-4T-15GB | 15.00 | 35.00 | 32.00 | 21.00 | 208.00 | 322.00 | 192.00 | 190.00 | 305.00 | Ø6 | 7.30 |
Item No. | Remark | ||||||||||
PG-A4 | AB Incrementall Encoder | ||||||||||
PG-C | Sin/Cos Encoder | ||||||||||
PG-C2 | |||||||||||
PG-C3 | |||||||||||
PG-B | UVW Encoder | ||||||||||
MD32PG5 | Absolute Encoder Endat and SSI Connector |