Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
---|---|
Output Type: | Single |
Principle of Work: | V/F Control Transducer |
Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage |
Output Frequency | 0~300Hz |
Performance | |
Overload Capacity | 150% rated output current for 15s |
Control Method | Vector control, V/F control |
Run Command Setting Method | Operation panel setting, external terminal setting, communication setting |
Speed Setting Method | Digital setting, analog setting, communication setting |
Speed Setting Resolution | Digital setting: 0.01Hz, Analog setting: 1% × maximum frequency |
Special Feature | |
Programmable Input & Output Terminals | Input& Output terminal function can be edited |
Process PID Adjustment Function | Built-in process PID module |
Protective function | |
Overvoltage Stall | Bus voltage automatic control to prevent overvoltage fault |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Input & Output | |
External analog power supply | +5V,load capacity 20mA |
External digital power supply | +24V,load capacity 100mA |
Analog Input | AI:Voltage 0~5V |
Digital Input | X1~X5 |
Digital Output | Y1 |
MODBUS Communication | A+,A- |
Operation Display | |
LED Display | Set frequency, output frequency, output voltage, output current, programming menu parameters and fault codes etc. |
Indicator Light | 3 unit indicators, 3 status indicators |
Environmental characteristics | |
Working Temperature | -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC |
Storage Environment Temperature | -40~+70ºC |
Application | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) |
H (mm) |
D (mm) |
W1 (mm) |
H1 (mm) |
Diameter (mm) |
GW (kg) |
1 Phase Input and 3 Phase Output 220V (-15%~+15% Tolerance) | |||||||||||
FC20-2S-0.2 | 0.20 | 2.30 | 1.60 | 3.00 | 53.00 | 160.00 | 102.00 | 80.00 | 89.50 | Ø4.5 | 1.08 |
FC20-2S-0.4 | 0.40 | 3.20 | 2.10 | 3.80 | 53.00 | 160.00 | 102.00 | 80.00 | 89.50 | Ø4.5 | 1.08 |
FC20-2S-0.75 | 0.75 | 4.00 | 3.70 | 5.60 | 53.00 | 160.00 | 102.00 | 80.00 | 89.50 | Ø4.5 | 1.08 |