Still deciding? Get samples of $ !
Order Sample
|
| Customization: | Available |
|---|---|
| Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
| Output Type: | Single & Three Phase |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
| Payment Methods: |
|
|---|---|
| Support payments in USD |
| Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
|---|
| Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
| Basic Specifications | |
| carrier frequency | 2kHz~16kHz;According to the load characteristics, the carrier frequency is automatically adjusted |
| Input Frequency Resolution | digital setting: 0.01Hz Analog setting: maximum frequency × 0.1% |
| Output Frequency Accuracy | Digital setting: maximum frequency × ±0.01% Analog setting: maximum frequency × ±0.01% |
| Control Method | Open-loop vector control (SVC)/closed-loop vector control (VC)/VF control |
| Starting torque | 0.5Hz/180%(SVC); 0Hz/200%(FVC) |
| Speed Range | 1:100(SVC)/1:1000(FVC) /1:50 (V/F) |
| Steady Speed Accuracy | ±0.5%(SVC) ±0.05%(FVC) |
| Overload Capacity | 150% rated current for 60 seconds; 180% rated current for 1 second. |
| Motor Tuning | Tuning with load; Tuning without load |
| Acceleration and deceleration curve | Linear or S-curve acceleration and deceleration methods; four sets of acceleration and deceleration time and four sets of S-curve settings; various combinations |
| Maintenance Control | Can be specified by any number of speeds |
| Multi-Speed Operation | Realize up to 8-speed operation |
| Automatic Voltage Regulator(AVR) | When the grid voltage changes, it can automatically keep the output voltage constant |
| Display and operation | |
| LED Display | Can display setting frequency, output frequency, output voltage, output current and other parameters |
| Parameter Copy | Fast copying of parameters with LED operator panel |
| Protective function | Power-on short circuit detection, input and output phase loss protection, overcurrent protection, overvoltage protection, under-voltage protection 40 kinds of protection |
| Key lock and function selection | Realize the partial or complete locking of the keys, and define the scope of action of some keys to prevent misuse |
| Personalization | |
| Power-on peripheral equipment safety self-test | It can realize safety detection of peripheral equipment such as grounding, short circuit etc. |
| Power Failure Emergency Operation | Simple and convenient implementation of emergency operation plan |
| Over-speed protection | Built-in elevator overspeed protection function; multiple action options |
| Judge speed deviation | Built-in speed deviation detection function; discover potential hidden dangers of elevators in time |
| Forced Shift Function | It has the function of forced speed change detection; it can effectively prevent the elevator from rushing to the top and squatting at the bottom |
| Direct Docking Function | Combined with direct docking commands for crawl-free operation |
| Motor temperature detection | Timely judge the motor temperature to eliminate potential safety hazards |
| Start Compensation | Three starting torque compensation methods: analog, digital, no weighing |
| QUICK Button | User-defined shortcut menu |
| Timing Control | Convenient timing control function |
| Input and output characteristics | |
| Run Command Channel | Two channels: operation panel given, control terminal given |
| Frequency Source | 4 frequency sources: digital reference, multi-speed reference, analog voltage 1 reference, and analog voltage 2 reference |
| Input Terminal | 10 digital input terminals, one of which can be used as high-speed pulse input, compatible with active PNP or NPN input mode 2 analog input terminals, one of which can only be used as voltage input, and the other can be used as voltage input or current input |
| Output Terminal | 3 digital output terminals 2 relay output terminals 1 channel of analog output terminal, 0/4 ~ 20mA or 0/2 ~ 10V can be selected respectively, which can realize the output of physical quantities such as set frequency and output frequency |
| Environmental characteristics | |
| Working temperature | -10~+40ºC, up to 50ºC, air temperature change is less than 0.5ºC/min |
| Storage Temperature | -40~+70ºC |
| Application Occasion | Indoors, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
| Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
| Humidity | Less than 95%RH, no condensation |
| Vibration Resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
| Protection Degree | IP20 |
| Pollution Level | Class 2 (dry, non-conductive dust pollution) |
| Item No. | Adaptable Motor (kW) | Input Current (A) | Output Current (A) | Rate Capacity (kVA) | W (mm) |
H (mm) |
D (mm) |
| 3 Phase Input and 3 Phase Output 380V (-15%~+15% Tolerance) | |||||||
| FC320L-4T-4.0GB | 4 | 10.50 | 9.00 | 5.90 | 160.00 | 248.00 | 183.00 |
| FC320L-4T-5.5GB | 5.5 | 14.80 | 13.00 | 8.90 | 160.00 | 248.00 | 183.00 |
| FC320L-4T-7.5GB-M | 7.5 | 20.50 | 18.00 | 11.00 | 160.00 | 248.00 | 183.00 |
| FC320L-4T-7.5GB | 7.5 | 20.50 | 18.00 | 11.00 | 208.00 | 322.00 | 192.00 |
| FC320L-4T-11GB | 11 | 29.00 | 27.00 | 17.00 | 208.00 | 322.00 | 192.00 |
| FC320L-4T-15GB | 15 | 36.00 | 33.00 | 21.00 | 208.00 | 322.00 | 192.00 |
| Item No. | Remark |
| 320L-PG-A | AB Incrementall Encoder |
| 320L-PG-B | UVW Encoder |
| 320L-PG-C | Sin/Cos Encoder |
| 320L-PG-C2 | Sin/Cos Encoder |
| 320L-PG-C3 | Sin/Cos Encoder |
| 320L-PG-C5 | Absolute Encoder Endat and SSI Connector |