Customization: | Available |
---|---|
Application: | High-performance Transducer, Three Phase Transducer, General Transducer, Single-phase Transducer, High Frequency Converter Transducer |
Output Type: | Single Phase & Three Phase |
Still deciding? Get samples of US$ 57/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Electrical Specification | |
Input Voltage | Single Phase/Three Phase 200~240V, Three Phase 380~440V Fluctuate no more than±10%,Imbalance Rate <3% |
Input Frequency | 50/60Hz ± 5% |
Output Voltage | 0V~Input Voltage |
Output Frequency | Vector Control:0~300Hz V/F Control:0~500Hz |
Performance | |
Overload Capacity | 150% rated output current for 1 minute, 180% rated output current for 2 seconds |
Control Method | Open-loop vector control (SVC), V/F control |
Run Command Setting Method | Operation Panel Setting, External Terminal Setting,Communication Setting |
Speed Setting Method | Digital setting, analog setting/pulse setting, communication setting |
Speed Setting Resolution | Digital setting: 0.01Hz, Analog setting: 1% X maximum frequency |
Speed Control Accuracy | SVC:±0.5% |
Speed Control Range | SVC:1:100 |
Torque Control Response | SVC:<200ms |
Starting Torque | SVC:150% rated torque/0.5Hz |
Special Feature | |
Programmable Input & Output Terminals | Input& Output terminal function can be edited |
Process PID Adjustment Function | Built-in process PID module |
Simple PLC Function | Built-in simple PLC module, which can realize timing and multi-segment frequency output |
Textile Wobble Function | Built-in textile swing frequency function module |
Water Supply Function | Built-in constant pressure water supply parameter macro |
Engraving Machine Function | Built-in engraving machine high frequency parameter macro |
Fire Mode | Built-in European fire mode parameter set |
Protective function | |
Overvoltage Stall | Bus voltage automatic control to prevent overvoltage fault |
Automatic Current Limiting Protection | Output current is automatically limited to prevent over-current faults |
Overload Pre-Alarm & Alarm | Overload Pre-warning and protection |
Output Phase Loss Protection | Output phase loss automatic detection and alarm function |
Overvoltage & Overflow Stall Control | Automatically limit current and voltage during operation to prevent frequent over-current and over-voltage tripping |
Output Short-to-Ground Protection | Effective protection function for output short circuit to ground |
Output Phase-to-Phase Short Circuit Protection | Output interphase short circuit effective protection function |
Input & Output | |
External analog power supply | External analog power supply |
External digital power supply | External digital power supply |
Analog Input | AI1:Voltage 0~10V/0-20mA AI2:Voltage 0~10V/0-20mA |
Analog Output | AO1:0~10V/0~20mA(Voltage/Current Optional) AO2:0~10V(Voltage Output) |
Digital Input | DI1~DI5(can be selected as a high-speed pulse signal) |
Digital Output | FM,AO2,FM can be selected as high-frequency pulse signal output |
Relay output | TA/TB/TC:Contact rating 250VAC/3A or 30VDC/1A |
MODBUS Communication | A+,B- |
Operation Display | |
LED Display | Set frequency, output frequency, output voltage, output current, motor speed, Output torque, digital terminals, status parameters, programming menu parameters and fault codes etc |
Indicator Light | 3 unit indicators, 4 status indicators |
Environmental characteristics | |
Working Temperature | -10~+40ºC, Maximum temperature is 50°C, Air Temperature change is less than 0.5°C/min,40~50ºC Derating is required, output current derating 2% for each 1ºC |
Storage Environment Temperature | -40~+70ºC |
Application | Indoor, free from direct sunlight, dust, corrosive gas, flammable gas, oil mist, water vapor, dripping water or salt etc. |
Altitude | Less than 1000 meters, derating is required for more than 1000 meters |
Humidity | Less than 95%RH, no condensation |
Vibration resistance | 3.5m/s² at 2-9Hz, 10m/s² at 9-200Hz (IEC60721-3-3) |
Protection Degree | IP20 |
Pollution Level | Class 2 (dry, non-conductive dust pollution) |
Certification | |
CE | The whole series has passed CE certification |